CVE-2026-9142 Details
Description
There is an insecure default credentials vulnerability in NI grpc-device when TLS configuration is not present and the server is bound beyond loopback. This may allow an unauthenticated user access to the server on the local network. This affects NI grpc-device 2.17.0 and prior versions.
A vulnerability exists in NI gRPC Device Server in versions through 2.17.0, allowing insecure default credentials when TLS is not configured and the server is accessible beyond the loopback interface. This could enable an unauthenticated user to access the server over the local network.
Users are advised to upgrade to NI gRPC Device Server version 2.18.0 or later.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
CISA-ADP
Assessed Jun 22, 2026References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-306 | Missing Authentication for Critical Function | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| ni instrumentstudio | <= 2025 2026 q1 2026 q2 |
CPE
Remediation
| |
| ni ni grpc device server | < 2.18.0 |
CPE
Remediation
| |
Change History
3 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 25, 2026 | Initial Analysis | [email protected] |
| Jun 22, 2026 | CVE Modified | CISA-ADP |
| Jun 19, 2026 | New CVE Received | [email protected] |