Not a U.S. government website. NDD is an independent vulnerability database by Volerion and is not affiliated with or endorsed by NIST or NVD.
CVE-2026-86105 Details
Description
An improper authorization vulnerability in Fireware OS's Access Portal reverse proxy allows an authenticated, low-privileged Access Portal user to access other web applications they are not authorized for by sending a specially crafted request for a different resource which they are authorized to access.
Metrics
CVSS 4.0 Severity and Vector Strings:
CNA: WatchGuard Technologies, Inc.CVSS-B:6 MEDIUMVector:CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
CISA-ADP
Assessed Sep 30, 2026Exploitation: NoneAutomatable: NoTechnical Impact: Partial
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://psirt.watchguard.com/CVE-2026-86105 | WatchGuard Technologies, Inc. | PatchVendor Advisory |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-176 | Improper Handling of Unicode Encoding | WatchGuard Technologies, Inc. |
| CWE-22 | Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') | WatchGuard Technologies, Inc. |
| CWE-285 | Improper Authorization | WatchGuard Technologies, Inc. |
Affected Products
| Product | Versions |
|---|---|
| watchguard fireware | >= 12.0, < 12.5.21 >= 12.12, < 12.12.3 >= 2025.0, < 2026.2.3 >= 2026.3, < 2026.3.2 |
CPE
Remediation
| |
Change History
3 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Oct 6, 2026 | Initial Analysis | [email protected] |
| Sep 30, 2026 | CVE Modified | CISA-ADP |
| Sep 30, 2026 | New CVE Received | WatchGuard Technologies, Inc. |