CVE-2026-1638 Details
Description
A security flaw has been discovered in Tenda AC21 1.1.1.1/1.dmzip/16.03.08.16. The impacted element is the function mDMZSetCfg of the file /goform/mDMZSetCfg. The manipulation of the argument dmzIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.
A stored command injection vulnerability has been identified in the Tenda AC21 router, specifically in version 1.1.1.1/1.dmzip/16.03.08.16. The issue arises in the 'mDMZSetCfg' function within the '/goform/mDMZSetCfg' endpoint. This vulnerability allows remote attackers to inject commands into the 'dmzIp' parameter, exploiting insufficient input validation. The injected commands are executed with root privileges, potentially leading to unauthorized access and control over the device.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
CISA-ADP
Assessed Jan 30, 2026References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://github.com/LX-LX88/cve/issues/26 | [email protected] | Broken Link |
| https://vuldb.com/?ctiid.343417 | [email protected] | Permissions RequiredVDB Entry |
| https://vuldb.com/?id.343417 | [email protected] | Third Party AdvisoryVDB Entry |
| https://vuldb.com/?submit.740871 | [email protected] | Third Party AdvisoryVDB Entry |
| https://www.tenda.com.cn/ | [email protected] | Product |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-77 | Improper Neutralization of Special Elements used in a Command ('Command Injection') | [email protected] |
| CWE-74 | Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') | [email protected] |
| CWE-77 | Improper Neutralization of Special Elements used in a Command ('Command Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| tenda ac21 firmware | 16.03.08.16 |
CPE
Remediation
| |
| tenda ac21 | All versions |
CPE
Remediation
| |
Change History
5 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Apr 29, 2026 | Data Remediation | [email protected] |
| Mar 9, 2026 | Initial Analysis | [email protected] |
| Jan 30, 2026 | New CVE Received | [email protected] |