Description

Incus before 7.6.0 contains an information disclosure vulnerability that allows project-restricted authenticated clients to receive other projects' OVN ACL logs because these events are broadcast with an empty project. Attackers can subscribe to network-acl events on one accessible project to observe internal IPs, ports, protocols, and allow/drop decisions across all projects.

Metrics

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.

Weakness Enumeration

CWE-IDCWE NameSource
CWE-200Exposure of Sensitive Information to an Unauthorized Actor[email protected]

Affected Products

ProductVersions
Incus
< v7.6.0 (semver)

CPE

  • No CPEs found in CPE dictionary for this product.

Remediation

  • Upgrade: >= v7.6.0moderate effort