CVE-2026-129809 Details

Description

ESC_foeprocess can be reached by an incoming mailbox frame before the application calls FOE_config to supply the file table and flush buffer pointers. When foe_cfg or its fbuffer field is NULL the handler dereferenced those pointers while processing the frame, causing a NULL pointer dereference.

Metrics

CVSS 3.x Severity and Vector Strings:

CNA: 4b71179a-3b92-4a9d-b9fc-af8b8ed579eeCVSS-B:5.3 MEDIUMVector:CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.

URLSource(s)Tag(s)
https://docs.rt-labs.com/security/advisories/rrtl-261119-01.html 4b71179a-3b92-4a9d-b9fc-af8b8ed579ee

Weakness Enumeration

CWE-IDCWE NameSource
CWE-476NULL Pointer Dereference4b71179a-3b92-4a9d-b9fc-af8b8ed579ee

Affected Products

No affected product data is available for this CVE.

Change History

1 change record found show changes