CVE-2025-65231 Details
Description
Barix Instreamer v04.06 and earlier is vulnerable to Cross Site Scripting (XSS) in the Web UI I/O & Serial configuration page, specifically the CTS close command user-input field which is stored and later rendered on the Status page.
A stored cross-site scripting vulnerability has been identified in Barix Instreamer devices running firmware through 04.06. The issue resides in the Web UI I/O & Serial configuration page, specifically within the CTS close command user-input field. This field allows an authenticated user to inject arbitrary HTML or JavaScript, which is then stored and rendered unescaped on the Status page. As a result, any user who views the Status page will have the injected script executed in their browser, potentially leading to a takeover of the administrative session, theft of credentials or cookies, unauthorized configuration changes, or defacement of the admin UI.
Barix has acknowledged this vulnerability and is preparing a patch for a future firmware release. Until the patch is available, users should restrict access to the web interface, regularly check the CTS close command field for suspicious content, and consider using a filtering reverse proxy or web application firewall to remove script tags from responses.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
CISA-ADP
Assessed Dec 9, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://github.com/iyadalkhatib98/My_CVES/tree/main/CVE-2025-65231 | CISA-ADP | ExploitThird Party Advisory |
| https://github.com/iyadalkhatib98/My_CVES/tree/main/CVE-2025-65231 | [email protected] | ExploitThird Party Advisory |
| https://help.barix.com/instreamer/user-manual | [email protected] | Product |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-79 | Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') | CISA-ADP |
Affected Products
| Product | Versions |
|---|---|
| barix instreamer firmware | <= 4.06 |
CPE
Remediation
| |
| barix instreamer | All versions |
CPE
Remediation
| |
Change History
6 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Oct 14, 2026 | CVE Translated | [email protected] |
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Dec 17, 2025 | Initial Analysis | [email protected] |
| Dec 11, 2025 | CVE Modified | CISA-ADP |
| Dec 8, 2025 | New CVE Received | [email protected] |