CVE-2025-58402 Details
Description
The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users.
A vulnerability exists in the CGM CLININET application due to the use of direct, sequential object identifiers 'MessageID' without adequate authorization checks. This flaw allows attackers to modify the 'MessageID' parameter in GET requests to access messages and attachments belonging to other users. The vulnerability affects all CGM CLININET versions prior to 2025.MS4.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
CISA-ADP
Assessed Mar 2, 2026References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://cert.pl/en/posts/2026/03/CVE-2025-10350/ | [email protected] | Third Party Advisory |
| https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html | [email protected] | Product |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-639 | Authorization Bypass Through User-Controlled Key | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| cgm clininet | < 2025.ms4 |
CPE
Remediation
| |
Change History
4 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Mar 9, 2026 | Initial Analysis | [email protected] |
| Mar 2, 2026 | New CVE Received | [email protected] |