Not a U.S. government website. NDD is an independent vulnerability database by Volerion and is not affiliated with or endorsed by NIST or NVD.
VOLERION
Volerion Security Research

NOT DEFERRED DATABASE

VULNERABILITIES

CVE-2025-54924 Details

ANALYZED


This CVE record has been analyzed and enriched by NVDAPI.com as an independent party.

Description

CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.

Metrics

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.

Weakness Enumeration

CWE-IDCWE NameSource
CWE-918Server-Side Request Forgery (SSRF)[email protected]

Affected Products

ProductVersions
Schneider Electric EcoStruxure Power Monitoring Expert
2022
2023
2024
2024 R2

CPE

  • cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*

Remediation

  • Mitigation:low effort

    Deploy and configure the Windows firewall to limit access to appropriate network segments.

  • Mitigation:low effort

    Enforce complex password policies.

  • Mitigation:low effort

    Review Server Access Permissions.

  • Mitigation:low effort

    Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically.

  • Mitigation:low effort

    Identify all accounts with access rights, especially those with elevated privileges or remote access.

  • Mitigation:low effort

    Limit access to essential users only.

  • Mitigation:low effort

    Revoke access for any user accounts that are not critical for system functionality or day-to-day operations.

  • Hotfix: Hotfix_269509_Release_13.1moderate effort

    Contact Schneider Electric’s Customer Care Center for assistance applying this hotfix.

  • Hotfix: Hotfix_269476_Release_13.1moderate effort

    Contact Schneider Electric’s Customer Care Center for assistance applying this hotfix.

  • Upgrade: 2024 R2moderate effort
  • Mitigation:low efforthttps://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm

    Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product.

  • Mitigation:low effort

    Ensure PME is running in an isolated network.

  • Mitigation:low effort

    Apply the principle of least privilege to ensure users have only the access necessary for their role(s).

Schneider Electric EcoStruxure Power Operation
All versions

CPE

  • No CPEs found in CPE dictionary for this product.

Remediation

  • No remediation found in references.

Change History

3 change records found show changes


QUICK INFO

CVE Dictionary Entry:
CVE-2025-54924
NVD Published Date:
Aug 20, 2025
NVD Last Modified:
Jun 17, 2026
Source:
[email protected]