CVE-2025-54850 Details
Description
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a sequence of Modbus RTU over TCP messages to port 503 using the Write Single Register function code (6). The attack sequence begins with a message to register 58112 with a value of 1000, indicating that a configuration change will follow. Next, a message is sent to register 29440 with a value corresponding to the new Modbus address to be configured. Finally, a message to register 57856 with a value of 161 commits the configuration change. After this configuration change, the device will be in a denial-of-service state.
A denial-of-service vulnerability has been identified in the Socomec DIRIS Digiware M-70 version 1.6.9, specifically within its Modbus TCP and Modbus RTU over TCP functionalities. This vulnerability allows an attacker to disrupt device communication by sending a series of unauthenticated Modbus RTU over TCP messages to port 503, using the Write Single Register function code. The attack involves modifying the device's Modbus address, which interrupts communication with all connected tools or devices across various Modbus networks. Once the address is changed, the device fails to respond to Modbus RTU over TCP requests, leading to a persistent denial-of-service condition.
Users can disable Modbus over Ethernet writing using the Cyber Security user profile in the device's WEBVIEW-M interface.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
CISA-ADP
Assessed Dec 1, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://talosintelligence.com/vulnerability_reports/TALOS-2025-2248 | [email protected] | Vendor Advisory |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-306 | Missing Authentication for Critical Function | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| socomec diris m-70 firmware | 1.6.9 |
CPE
Remediation
| |
| socomec diris m-70 | All versions |
CPE
Remediation
| |
Change History
5 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Sep 26, 2026 | CVE Translated | [email protected] |
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Dec 5, 2025 | Initial Analysis | [email protected] |
| Dec 1, 2025 | New CVE Received | [email protected] |