CVE-2025-5446 Details
Description
A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A critical command injection vulnerability has been identified in Linksys RE6500, RE6250, RE6300, RE6350, RE7000, and RE9000 routers, all running specific firmware versions. The issue arises in the RP_checkCredentialsByBBS function, where the 'pwd' argument can be manipulated to inject operating system commands. This vulnerability can be exploited remotely, and details of the exploit have been made public.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
CISA-ADP
Assessed Jun 2, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_9/9.md | [email protected] | ExploitThird Party Advisory |
| https://vuldb.com/?ctiid.310785 | [email protected] | Permissions RequiredVDB Entry |
| https://vuldb.com/?id.310785 | [email protected] | Third Party AdvisoryVDB Entry |
| https://vuldb.com/?submit.584368 | [email protected] | Third Party AdvisoryVDB Entry |
| https://www.linksys.com/ | [email protected] | Product |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-78 | Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | [email protected] |
| CWE-77 | Improper Neutralization of Special Elements used in a Command ('Command Injection') | [email protected] |
| CWE-78 | Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| linksys re9000 firmware | 1.0.04.002 |
CPE
Remediation
| |
| linksys re9000 | All versions |
CPE
Remediation
| |
| linksys re6250 firmware | 1.0.04.001 |
CPE
Remediation
| |
| linksys re6250 | All versions |
CPE
Remediation
| |
| linksys re6300 firmware | 1.2.07.001 |
CPE
Remediation
| |
| linksys re6300 | All versions |
CPE
Remediation
| |
| linksys re6350 firmware | 1.0.04.001 |
CPE
Remediation
| |
| linksys re6350 | All versions |
CPE
Remediation
| |
| linksys re7000 firmware | 1.1.05.003 |
CPE
Remediation
| |
| linksys re7000 | All versions |
CPE
Remediation
| |
| linksys re6500 firmware | 1.0.013.001 |
CPE
Remediation
| |
| linksys re6500 | All versions |
CPE
Remediation
| |
Change History
4 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Jun 25, 2025 | Initial Analysis | [email protected] |
| Jun 2, 2025 | New CVE Received | [email protected] |