Description
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
A vulnerability exists in certain POWER METER SICAM Q100 and Q200 devices, where the SMTP account password is stored in plain text. This issue affects POWER METER SICAM Q100 models 7KG9501-0AA01-0AA1, 7KG9501-0AA01-2AA1, 7KG9501-0AA31-0AA1, and 7KG9501-0AA31-2AA1, all versions from 2.60 up to but not including 2.62, as well as the POWER METER SICAM Q200 family, all versions from 2.70 up to but not including 2.80. The plain text storage of passwords could allow an authenticated local attacker to extract the password and misuse the SMTP service for various purposes.
Siemens has released new versions for the affected products. POWER METER SICAM Q200 users should update to version 2.80 or later. For POWER METER SICAM Q100, consult the Siemens support portal for guidance on the latest available version.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Aug 12, 2025CISA-ADP
Assessed Aug 12, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://cert-portal.siemens.com/productcert/html/ssa-529291.html | [email protected] | AdvisoryBundleRemedyVendor |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-312 | Cleartext Storage of Sensitive Information | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| Siemens POWER METER SICAM Q100 | >= V2.60, < V2.62 >= V2.70, < V2.80 |
CPE
Remediation
| |
| Siemens POWER METER SICAM Q200 | All versions |
CPE
Remediation
| |