Description

A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.

Metrics

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.

Weakness Enumeration

CWE-IDCWE NameSource
CWE-288Authentication Bypass Using an Alternate Path or Channel[email protected]

Affected Products

ProductVersions
Siemens SINUMERIK 828D
< V4.95 SP5

CPE

  • cpe:2.3:h:siemens:sinumerik_828d:*:*:*:*:*:*:*:*
  • cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*

Remediation

  • Upgrade: V4.95 SP5moderate effort
  • Mitigation:low effort

    Close VNC port on X130 via HMI setting.

  • Mitigation:low effort

    Set VNC Password on X120 and X130.

  • Mitigation:low effort

    Change TCU.ini setting to "ExternalViewerReqTimeoutMode=0".

Siemens SINUMERIK 840D sl
< V4.95 SP5

CPE

  • cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_840_d_sl:*:*:*:*:*:*:*:*

Remediation

  • Upgrade: V4.95 SP5moderate effort
  • Mitigation:low effort

    Close VNC port on X130 via HMI setting.

  • Mitigation:low effort

    Set VNC Password on X120 and X130.

  • Mitigation:low effort

    Change TCU.ini setting to "ExternalViewerReqTimeoutMode=0".

Siemens SINUMERIK MC
All versions

CPE

  • cpe:2.3:h:siemens:sinumerik_mc:*:*:*:*:*:*:*:*

Remediation

  • No remediation found in references.
Siemens SINUMERIK MC V1.15
All versions

CPE

  • cpe:2.3:h:siemens:sinumerik_mc_mcu_1720:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_operate:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_operate_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_pcu_50.5:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_pcu_50.5_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_pcu50.5-c:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_pcu50.5-p_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:sinumerik_pcu50.5-p:*:*:*:*:*:*:*:*

Remediation

  • No remediation found in references.
Siemens SINUMERIK ONE
< V6.25 SP1
< V6.15 SP5

CPE

  • cpe:2.3:h:siemens:sinumerik_one:*:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:sinumerik_one_firmware:*:*:*:*:*:*:*:*

Remediation

  • Upgrade: V6.25 SP1moderate effort
  • Upgrade: V6.15 SP5moderate effort
  • Mitigation:low effort

    Close VNC port on X130 via HMI setting.

  • Mitigation:low effort

    Set VNC Password on X120 and X130.

  • Mitigation:low effort

    Change TCU.ini setting to "ExternalViewerReqTimeoutMode=0".