CVE-2025-27594 Details
Description
The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack.
A vulnerability exists in the SICK DL100-2xxxxxxx series, all firmware versions, due to the use of an unencrypted, proprietary communication protocol. This protocol transmits configuration data and handles device authentication. As a result, an attacker could intercept the authentication hash and exploit it to gain unauthorized access to the device using a pass-the-hash technique.
SICK recommends applying general security practices when operating the DL100 devices. This includes minimizing network exposure, restricting network access, and following the SICK Operating Guidelines for Cybersecurity. These measures can help mitigate the associated security risks.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Mar 14, 2025CISA-ADP
Assessed Mar 14, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-319 | Cleartext Transmission of Sensitive Information | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| SICK DL100-2xxxxxxx | All versions |
CPE
Remediation
| |
Change History
3 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Mar 14, 2025 | New CVE Received | [email protected] |