CVE-2025-15391 Details
Description
A weakness has been identified in D-Link DIR-806A 100CNb11. Affected is the function ssdpcgi_main of the component SSDP Request Handler. This manipulation causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited. This vulnerability only affects products that are no longer supported by the maintainer.
A command injection vulnerability has been identified in the D-Link DIR-806A router running firmware version 100CNb11. The issue arises in the SSDP Request Handler component, specifically within the ssdpcgi_main function. This vulnerability allows remote attackers to execute arbitrary system commands on the device by sending specially crafted SSDP requests. The exploitation of this vulnerability is made possible because the HTTP_ST header, which can be controlled by the client, is not properly sanitized before being passed to a system() call. As a result, attackers can manipulate the request to execute commands of their choice on the router.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
CISA-ADP
Assessed Jan 2, 2026References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://github.com/ccc-iotsec/cve-/blob/D-Link/D-Link%20DIR-806A%E6%9C%AA%E6%8E%88%E6%9D%83RCE.md | [email protected] | ExploitThird Party Advisory |
| https://vuldb.com/?ctiid.339152 | [email protected] | Permissions RequiredVDB Entry |
| https://vuldb.com/?id.339152 | [email protected] | Third Party AdvisoryVDB Entry |
| https://vuldb.com/?submit.727637 | [email protected] | Third Party AdvisoryVDB Entry |
| https://www.dlink.com/ | [email protected] | Product |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-77 | Improper Neutralization of Special Elements used in a Command ('Command Injection') | [email protected] |
| CWE-74 | Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') | [email protected] |
| CWE-77 | Improper Neutralization of Special Elements used in a Command ('Command Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| dlink dir-806a firmware | 100cnb11 |
CPE
Remediation
| |
| dlink dir-806a | All versions |
CPE
Remediation
| |
Change History
6 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Sep 23, 2026 | CVE Translated | [email protected] |
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Apr 29, 2026 | Data Remediation | [email protected] |
| Jan 14, 2026 | Initial Analysis | [email protected] |
| Dec 31, 2025 | New CVE Received | [email protected] |