CVE-2025-12233 Details
Description
A flaw has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. Executing a manipulation of the argument page can lead to buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.
A critical buffer overflow vulnerability has been identified in the Tenda CH22 router, specifically in version 1.0.0.1. The issue arises in the SafeUrlFilter endpoint, where the fromSafeUrlFilter function processes the user-controlled page parameter using sprintf. This method of handling input lacks proper length validation, allowing data larger than 256 bytes to overwrite adjacent memory. Such memory corruption can lead to application crashes, arbitrary code execution, or unauthorized access to sensitive information. The vulnerability can be exploited remotely, posing significant risks to the device's stability and security.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
CISA-ADP
Assessed Oct 27, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://github.com/QIU-DIE/CVE/issues/14 | CISA-ADP | ExploitThird Party Advisory |
| https://github.com/QIU-DIE/CVE/issues/14 | [email protected] | ExploitThird Party Advisory |
| https://vuldb.com/?ctiid.329903 | [email protected] | Permissions RequiredVDB Entry |
| https://vuldb.com/?id.329903 | [email protected] | Third Party AdvisoryVDB Entry |
| https://vuldb.com/?submit.673714 | [email protected] | Third Party AdvisoryVDB Entry |
| https://www.tenda.com.cn/ | [email protected] | Product |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-120 | Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') | [email protected] |
| CWE-119 | Improper Restriction of Operations within the Bounds of a Memory Buffer | [email protected] |
| CWE-120 | Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| tenda ch22 firmware | 1.0.0.1 |
CPE
Remediation
| |
| tenda ch22 | All versions |
CPE
Remediation
| |
Change History
7 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Oct 8, 2026 | CVE Translated | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Jun 17, 2026 | CVE Modified | [email protected] |
| Feb 24, 2026 | CVE Modified | [email protected] |
| Oct 27, 2025 | Initial Analysis | [email protected] |
| Oct 27, 2025 | CVE Modified | CISA-ADP |
| Oct 27, 2025 | New CVE Received | [email protected] |