Not a U.S. government website. NDD is an independent vulnerability database by Volerion and is not affiliated with or endorsed by NIST or NVD.
VOLERION
Volerion Security Research

NOT DEFERRED DATABASE

VULNERABILITIES

CVE-2025-1094 Details

ANALYZED


This CVE record has been analyzed and enriched by NVDAPI.com as an independent party.

Description

Improper neutralization of quoting syntax in PostgreSQL libpq functions PQescapeLiteral(), PQescapeIdentifier(), PQescapeString(), and PQescapeStringConn() allows a database input provider to achieve SQL injection in certain usage patterns. Specifically, SQL injection requires the application to use the function result to construct input to psql, the PostgreSQL interactive terminal. Similarly, improper neutralization of quoting syntax in PostgreSQL command line utility programs allows a source of command line arguments to achieve SQL injection when client_encoding is BIG5 and server_encoding is one of EUC_TW or MULE_INTERNAL. Versions before PostgreSQL 17.3, 16.7, 15.11, 14.16, and 13.19 are affected.

Metrics

CVSS 3.x Severity and Vector Strings:

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.

Weakness Enumeration

CWE-IDCWE NameSource
CWE-149Improper Neutralization of Quoting SyntaxPostgreSQL

Affected Products

ProductVersions
PostgreSQL
< 17.3
< 16.7
< 15.11
< 14.16
< 13.19

CPE

  • cpe:2.3:a:postgresql:postgresql:*:*:*:*:*:*:*:*
  • cpe:2.3:a:postgresql:postgresql:*:*:*:*:*:debian:*:*
  • cpe:2.3:a:postgresql:postgresql:*:*:*:*:*:ubuntu:*:*

Remediation

  • Upgrade: 17.3moderate effort
  • Upgrade: 16.7moderate effort
  • Upgrade: 15.11moderate effort
  • Upgrade: 14.16moderate effort
  • Upgrade: 13.19moderate effort
  • Upgrade: 13.19-0+deb11u1moderate effort
  • Upgrade: 13.20-0+deb11u1moderate effort
Debian
All versions

CPE

  • cpe:2.3:o:debian:debian_linux:*:*:*:*:*:*:*:*

Remediation

  • No remediation found in references.
NetApp
All versions

CPE

  • cpe:2.3:a:netapp:active_iq:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:astra_trident:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:brocade_network_advisor:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:cloud_backup:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:data_infrastructure_insights_acquisition_unit:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:data_ontap:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:data_ontap:*:*:*:*:*:7-mode:*:*
  • cpe:2.3:a:netapp:e-series_santricity_management:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:e-series_santricity_management:*:*:*:*:*:vcenter:*:*
  • cpe:2.3:a:netapp:e-series_santricity_management:*:*:*:*:*:vmware_sra:*:*
  • cpe:2.3:a:netapp:e-series_santricity_management:*:*:*:*:*:vmware_vasa:*:*
  • cpe:2.3:a:netapp:e-series_santricity_management:*:*:*:*:*:vmware_vcenter:*:*
  • cpe:2.3:a:netapp:e-series_santricity_unified_manager:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:hyper_converged_infrastructure:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:max_data:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:netapp_plug-in:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:netapp_xcp_smb:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:netcache:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:ontap:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:ontap_9:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:os_controller:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:santricity_unified_manager:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:snapdriver:*:*:*:*:*:unix:*:*
  • cpe:2.3:a:netapp:snapmanager:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:snapmanager:*:*:*:*:*:hyper-v:*:*
  • cpe:2.3:a:netapp:snapmanager:*:*:*:*:*:oracle:*:*
  • cpe:2.3:a:netapp:snapmanager:*:*:*:*:*:sap:*:*
  • cpe:2.3:a:netapp:snapprotect:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:solidfire:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:storage_automation_store:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:storagegrid:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:storagegrid_webscale:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:system_manager:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:system_setup:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:trident:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:virtual_file_mangemer:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:virtual_storage_console:*:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:virtual_storage_console:*:*:*:*:*:vmware_vsphere:*:*
  • cpe:2.3:a:netapp:virtual_storage_console:*:*:*:*:*:vsphere:*:*
  • cpe:2.3:h:netapp:500f:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:8300:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:8700:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:a220:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:a250:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:a320:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:a400:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:a800:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:aff_500f:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:aff_8300:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:aff_a200:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:aff_a700:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:aff_a700s:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:aff_c190:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:c190:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:c250:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:c400:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:cn1610:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:fabric-attached_storage_8300:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:fabric-attached_storage_a400:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:fas2600:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:fas26x0:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:fas27x0:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:fas8700:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:fas9000:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:h300e:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:h300s:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:h410s:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:h500s:*:*:*:*:*:*:*:*
  • cpe:2.3:h:netapp:storagegrid:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:500f_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:8300_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:8700_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a220_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a250_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a320_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a400_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a800_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_500f_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_8300_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_a200_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_a700_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_a700s_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_c190_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:brocade_fabric_os:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:c190_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:c250_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:c400_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:cluster_data_ontap:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:clustered_data_ontap:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:cn1610_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:data_ontap:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:data_ontap:*:*:*:*:*:7-mode:*:*
  • cpe:2.3:o:netapp:element:*:*:*:*:*:vcenter_server:*:*
  • cpe:2.3:o:netapp:element_os:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:element_software:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fabric-attached_storage_a400_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fas2600_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fas26x0_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fas27x0_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fas8700_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fas9000_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h300e_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h300s_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h410s_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h500s_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:storagegrid_firmware:*:*:*:*:*:*:*:*

Remediation

  • No remediation found in references.

Change History

11 change records found show changes


QUICK INFO

CVE Dictionary Entry:
CVE-2025-1094
NVD Published Date:
Feb 13, 2025
NVD Last Modified:
Nov 3, 2026
Source:
PostgreSQL
CVE-2025-1094 Details - Not Deferred