CVE-2025-0593 Details
Description
The vulnerability may allow a remote low priviledged attacker to run arbitrary shell commands by using lower-level functions to interact with the device.
A command injection vulnerability has been identified in the SICK Lector8xx and SICK InspectorP8xx product lines. This vulnerability allows remote attackers with low privileges to execute arbitrary shell commands on the affected devices. The issue arises from the ability to manipulate firmware files or use lower-level functions to interact with the device's command execution environment.
Users are advised to upgrade to the latest versions of the Lector8xx (version 2.4.0 or later) and the InspectorP8xx (version 3.11.1 or later) that include patches for this vulnerability. It is also recommended to set a secure password, following the operating instructions available in the reference section.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Feb 14, 2025CISA-ADP
Assessed Feb 14, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-77 | Improper Neutralization of Special Elements used in a Command ('Command Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| SICK Lector8xx | All versions |
CPE
Remediation
| |
| SICK InspectorP8xx | All versions |
CPE
Remediation
| |
Change History
3 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Feb 14, 2025 | New CVE Received | [email protected] |
Volerion