CVE-2024-8893 Details
Description
Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1.
A vulnerability exists in the GoodWe GW1500-XS inverter, specifically in version 1.1.2.1, due to hard-coded credentials in the Wi-Fi BOX. This flaw allows anyone in physical proximity to the device to access the inverter's web interface over Wi-Fi. Through this interface, an individual could modify the inverter's network settings or restart the device.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Feb 14, 2025CISA-ADP
Assessed Feb 14, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://os-s.net/publications/advisories/CVE-2024-8893.pdf | ENISA | AdvisoryPartial Content |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-798 | Use of Hard-coded Credentials | ENISA |
Affected Products
| Product | Versions |
|---|---|
| GoodWe Technologies Co., Ltd. GW1500-XS | All versions |
CPE
Remediation
| |
Change History
3 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | ENISA |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Feb 14, 2025 | New CVE Received | ENISA |
Volerion