CVE-2024-56181 Details
Description
A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions < V36.01.03), SIMATIC IPC RC-543B (All versions < V35.01.12), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC RW-543B (All versions < V35.02.10), SIMATIC IPC127E (All versions < V27.01.11), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATIC IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions < V21.01.21), SIMATIC IPC477E (All versions < V21.01.21), SIMATIC IPC477E PRO (All versions < V21.01.21), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions < V25.02.15), SIMATIC IPC647E (All versions < V25.02.15), SIMATIC IPC677E (All versions < V25.02.15), SIMATIC IPC847E (All versions < V25.02.15), SIMATIC ITP1000 (All versions). The affected devices have insufficient protection mechanism for the EFI(Extensible Firmware Interface) variables stored on the device. This could allow an authenticated attacker to alter the secure boot configuration without proper authorization by directly communicate with the flash controller.
A vulnerability exists in various Siemens SIMATIC products, including Field PG M5, IPC BX series, IPC PX series, and several others, all versions. The issue stems from inadequate protection of Extensible Firmware Interface (EFI) variables, which could enable an authenticated attacker to unauthorizedly alter the secure boot configuration by directly communicating with the flash controller.
Siemens has released new BIOS versions for several affected products. For products like the SIMATIC ITP1000, where no fix is currently available, Siemens recommends restricting access to root or administrator permissions. General security guidelines suggest protecting network access to devices and following Siemens' operational recommendations for Industrial Security.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Mar 11, 2025CISA-ADP
Assessed Mar 11, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://cert-portal.siemens.com/productcert/html/ssa-216014.html | [email protected] | AdvisoryBundleRemedyVendor |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-693 | Protection Mechanism Failure | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| Siemens SIMATIC Field PG | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC BX-21A | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC BX-32A | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC BX-39A | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC BX-59A | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC PX-32A | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC PX-39A | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC PX-39A PRO | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC RC-543B | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC RW-543A | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC127E | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC227E | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC227G | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC277E | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC277G | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC277G PRO | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC3000 SMART V3 | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC327G | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC347G | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC377G | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC427E | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC477E | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC477E PRO | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC527G | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC627E | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC647E | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC677E | All versions |
CPE
Remediation
| |
| Siemens SIMATIC IPC847E | All versions |
CPE
Remediation
| |
| Siemens SIMATIC ITP1000 | All versions |
CPE
Remediation
| |
Change History
9 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Sep 8, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Jun 17, 2026 | CVE Modified | [email protected] |
| May 12, 2026 | CVE Modified | [email protected] |
| Apr 14, 2026 | CVE Modified | [email protected] |
| Feb 10, 2026 | CVE Modified | [email protected] |
| Nov 11, 2025 | CVE Modified | [email protected] |
| Jun 10, 2025 | CVE Modified | [email protected] |
| Mar 11, 2025 | New CVE Received | [email protected] |
Volerion