CVE-2024-54678 Details
Description
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.
A deserialization vulnerability has been identified in multiple Siemens engineering platforms, including SIMATIC PCS neo, STEP 7, WinCC, SIMOCODE ES, SINAMICS Startdrive, SIRIUS Safety ES, SIRIUS Soft Starter ES, and TIA Portal Cloud, all versions. The vulnerability arises because these products do not properly sanitize input received through a Windows Named Pipe, which is accessible to all local users. This flaw could enable an authenticated local attacker to cause type confusion and execute arbitrary code within the affected application.
Siemens has released new versions for several affected products and recommends updating to the latest versions. For products where fixes are not yet available, Siemens advises specific countermeasures. On desktop systems, execute the affected software on Windows hosts with only a single user configured. On server systems, restrict access at the operating system level to administrators only.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Aug 12, 2025CISA-ADP
Assessed Aug 12, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://cert-portal.siemens.com/productcert/html/ssa-693808.html | [email protected] | AdvisoryRemedyVendor |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-502 | Deserialization of Untrusted Data | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| Siemens SIMATIC PCS neo | All versions |
CPE
Remediation
| |
| Siemens SIMATIC S7-PLCSIM | All versions |
CPE
Remediation
| |
| Siemens SIMATIC STEP 7 | All versions |
CPE
Remediation
| |
| Siemens SIMATIC WinCC | All versions |
CPE
Remediation
| |
| Siemens SIMOCODE ES | All versions |
CPE
Remediation
| |
| Siemens SIMOTION SCOUT TIA | All versions |
CPE
Remediation
| |
| Siemens SINAMICS Startdrive | All versions |
CPE
Remediation
| |
| Siemens SIRIUS Safety ES | All versions |
CPE
Remediation
| |
| Siemens SIRIUS Soft Starter ES | All versions |
CPE
Remediation
| |
| Siemens TIA Portal Cloud | All versions |
CPE
Remediation
| |
| Siemens TIA Portal Test Suite | All versions |
CPE
Remediation
| |
Change History
8 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Nov 10, 2026 | CVE Modified | [email protected] |
| Oct 13, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Jun 9, 2026 | CVE Modified | [email protected] |
| Dec 9, 2025 | CVE Modified | [email protected] |
| Oct 14, 2025 | CVE Modified | [email protected] |
| Aug 12, 2025 | New CVE Received | [email protected] |
Volerion