Not a U.S. government website. NDD is an independent vulnerability database by Volerion and is not affiliated with or endorsed by NIST or NVD.
VOLERION
Volerion Security Research

NOT DEFERRED DATABASE

VULNERABILITIES

CVE-2024-43661 Details

ANALYZED


This CVE record has been analyzed and enriched by NVDAPI.com as an independent party.

Description

The <redacted>.so library, which is used by <redacted>, is vulnerable to a buffer overflow in the code that handles the deletion of certificates. This buffer overflow can be triggered by providing a long file path to the <redacted> action of the <redacted>.exe CGI binary or to the <redacted>.sh CGI script. This binary or script will write this file path to <redacted>, which is then read by <redacted>.so This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – An attacker will have to find this exploit by either obtaining the binaries involved in this vulnerability, or by trial and error. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe CGI binary or <redacted>.sh script to trigger the vulnerability, or convince a user with such access send an HTTP request that triggers it. Impact: High – The <redacted> process, which we assume is responsible for OCPP communication, will keep crashing after performing the exploit. This happens because the buffer overflow causes the process to segfault before <redacted> is removed. This means that, even though <redacted> is automatically restarted, it will crash again as soon as it tries to parse the text file. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I).

Metrics

CVSS 3.x Severity and Vector Strings:

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.

Weakness Enumeration

CWE-IDCWE NameSource
CWE-121Stack-based Buffer Overflow[email protected]

Affected Products

ProductVersions
Iocharger Iocharger firmware
All versions

CPE

  • No CPEs found in CPE dictionary for this product.

Remediation

  • No remediation found in references.

Change History

4 change records found show changes


QUICK INFO

CVE Dictionary Entry:
CVE-2024-43661
NVD Published Date:
Jan 9, 2025
NVD Last Modified:
Jun 17, 2026
Source:
[email protected]
CVE-2024-43661 Details - Not Deferred