CVE-2024-43656 Details
Description
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
A command injection vulnerability has been identified in Iocharger firmware for AC model chargers, affecting versions prior to 24120701. This vulnerability allows authenticated users to execute operating system commands as the root user on the charging station. The issue arises from improper neutralization of special elements used in commands, enabling manipulation of backup files to include malicious CGI scripts that can be executed remotely. The vulnerability has a moderate likelihood of exploitation, as it requires knowledge of the file structure and access to upload modified backup files. However, once exploited, it grants full control over the charging station, with potential safety implications due to the high power involved.
Iocharger has released a firmware update version 24120701 that addresses this vulnerability. For versions 25010801, which fixes an additional three vulnerabilities, Iocharger products can contact their distributor or reach out to Iocharger directly via email for the updated firmware.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Jan 9, 2025CISA-ADP
Assessed Jan 9, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://csirt.divd.nl/CVE-2024-43656/ | [email protected] | Advisory |
| https://csirt.divd.nl/DIVD-2024-00035/ | [email protected] | BundleRemedyTechnical Description |
| https://iocharger.com | [email protected] | Vendor |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-434 | Unrestricted Upload of File with Dangerous Type | [email protected] |
| CWE-78 | Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| Iocharger Home | All versions |
CPE
Remediation
| |
| Iocharger Pedestal | All versions |
CPE
Remediation
| |
| Iocharger AC models | All versions |
CPE
Remediation
| |
Change History
4 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Jan 9, 2025 | CVE Modified | CISA-ADP |
| Jan 9, 2025 | New CVE Received | [email protected] |
Volerion