Description
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
A command injection vulnerability has been identified in Iocharger firmware for AC models, all versions prior to 25010801. This vulnerability allows authenticated users to execute OS commands as root on the charging station. The issue arises from improper neutralization of special elements used in commands, enabling OS command injection. While the vulnerability is present in the web interface, it may be more challenging to exploit as it requires access to a specific binary, similar to one used in the Iocharger Pedestal charging station. An attacker would need a low-privilege account or to persuade a user with such access to send a crafted HTTP request.
Iocharger has released firmware version 25010801, which addresses this vulnerability. The firmware is available through Iocharger distributors. Users should also change default passwords and ensure their Iocharger devices are not exposed to untrusted networks.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Jan 9, 2025CISA-ADP
Assessed Jan 9, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://csirt.divd.nl/CVE-2024-43654/ | [email protected] | AdvisoryTechnical Description |
| https://csirt.divd.nl/DIVD-2024-00035/ | [email protected] | BundleRemedyTechnical Description |
| https://iocharger.com | [email protected] | Vendor |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-250 | Execution with Unnecessary Privileges | [email protected] |
| CWE-78 | Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| Iocharger Home | All versions |
CPE
Remediation
| |
| Iocharger Pedestal | All versions |
CPE
Remediation
| |
| Iocharger AC EV charger | All versions |
CPE
Remediation
| |
Change History