CVE-2024-43651 Details
Description
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
A command injection vulnerability has been identified in Iocharger firmware for AC models prior to version 241207101. This vulnerability allows authenticated users to execute operating system commands as the root user on the affected charging station. The issue arises from improper handling of special elements in commands, which could be exploited by convincing a user with low privileges to send a crafted HTTP request. Once exploited, the attacker could gain full control over the charging station, including the ability to add, modify, or delete files and services. Additionally, because this is an electric vehicle charger managing significant power, there are potential safety implications.
Users are advised to update to Iocharger firmware version 24120701 or later, which addresses this vulnerability. Firmware version 25010801 is also available and fixes additional vulnerabilities. If not contacted by a distributor for the update, users should reach out to Iocharger directly at [email protected].
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Jan 9, 2025CISA-ADP
Assessed Jan 9, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://csirt.divd.nl/CVE-2024-43651/ | [email protected] | AdvisoryTechnical Description |
| https://csirt.divd.nl/DIVD-2024-00035/ | [email protected] | BundleRemedyTechnical Description |
| https://iocharger.com | [email protected] | Vendor |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-250 | Execution with Unnecessary Privileges | [email protected] |
| CWE-78 | Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| Iocharger Home | All versions |
CPE
Remediation
| |
| Iocharger Pedestal | All versions |
CPE
Remediation
| |
| Iocharger AC models | All versions |
CPE
Remediation
| |
Change History
3 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Jan 9, 2025 | New CVE Received | [email protected] |
Volerion