CVE-2024-43650 Details
Description
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
A command injection vulnerability has been identified in Iocharger firmware for AC models, affecting versions prior to 24120701. This vulnerability allows authenticated users to execute operating system commands as root on the charging station. The issue arises from improper neutralization of special elements used in commands, enabling command injection via a specific binary. While the vulnerability requires a low-privilege account to access the binary, it can potentially be exploited by convincing a user with the necessary access to send a crafted HTTP request.
Iocharger has released a firmware update version 24120701 that addresses this vulnerability. Version 25010801, also available, fixes additional vulnerabilities. The firmware can be obtained through Iocharger distributors. If not contacted by a distributor, users can reach out to Iocharger directly via email for the update.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Jan 9, 2025CISA-ADP
Assessed Jan 9, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://csirt.divd.nl/CVE-2024-43650/ | [email protected] | AdvisoryTechnical Description |
| https://csirt.divd.nl/DIVD-2024-00035/ | [email protected] | BundleRemedyTechnical Analysis |
| https://iocharger.com | [email protected] | Vendor |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-250 | Execution with Unnecessary Privileges | [email protected] |
| CWE-78 | Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| Iocharger Home | All versions |
CPE
Remediation
| |
| Iocharger Pedestal | All versions |
CPE
Remediation
| |
| Iocharger AC models | All versions |
CPE
Remediation
| |
Change History
3 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Jan 9, 2025 | New CVE Received | [email protected] |
Volerion