Description
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
A command injection vulnerability has been identified in Iocharger firmware for AC models prior to version 24120701. This vulnerability allows authenticated users to inject commands through a specific parameter in a <redacted>.exe request, leading to remote code execution as the root user. The issue arises because the injection point is not a typical location for such vulnerabilities, making it likely that an attacker would need to reverse-engineer the firmware or experiment with various <redacted> fields to discover it. Additionally, the attacker must have a low-privilege account to access the <redacted> binary or persuade a user with the necessary privileges to execute a malicious payload.
Iocharger has released a firmware update version 24120701 for all AC models, which addresses this vulnerability. For models requiring further updates, version 25010801 is available. Firmware can be obtained through Iocharger distributors or by contacting Iocharger directly.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Jan 9, 2025CISA-ADP
Assessed Jan 9, 2025References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://csirt.divd.nl/CVE-2024-43649/ | [email protected] | AdvisoryTechnical Description |
| https://csirt.divd.nl/DIVD-2024-00035/ | [email protected] | BundleRemedyTechnical Description |
| https://iocharger.com | [email protected] | Vendor |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-250 | Execution with Unnecessary Privileges | [email protected] |
| CWE-78 | Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| Iocharger Home | All versions |
CPE
Remediation
| |
| Iocharger Pedestal | All versions |
CPE
Remediation
| |
| Iocharger AC models | All versions |
CPE
Remediation
| |
Change History
4 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Jan 9, 2025 | CVE Modified | CISA-ADP |
| Jan 9, 2025 | New CVE Received | [email protected] |