CVE-2023-51587 Details

Description

Voltronic Power ViewPower getModbusPassword Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the getModbusPassword method. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-22073.

Metrics

CVSS 3.x Severity and Vector Strings:

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.

Weakness Enumeration

CWE-IDCWE NameSource
CWE-306Missing Authentication for Critical Function[email protected]

Affected Products

ProductVersions
voltronicpower viewpower
1.04.21353

CPE

  • cpe:2.3:a:voltronicpower:viewpower:1.04.21353:*:*:*:-:*:*:*