CVE-2022-50980 Details
Description
A unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via CAN.
A vulnerability exists in IDS VibroLine devices running version 5.0 Firmware 2.1.1340 to 2.1.1387 on the VLX1, VLX2, VLX4, VLX6, and VLX8 HD 5.0 models. The vulnerability allows an unauthenticated adjacent attacker to disrupt operations by switching between multiple configuration presets via CAN. This issue could interfere with normal device functions, especially if more than one configuration preset is active.
Users can limit access to the CAN bus to trustworthy devices and remove any unnecessary configuration presets. For devices currently running the vulnerable firmware, an update to version 2.1.1866 or later is recommended.
Metrics
CVSS 4.0 Severity and Vector Strings:
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
Volerion
Assessed Feb 2, 2026CISA-ADP
Assessed Feb 2, 2026References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://www.innomic.com/.well-known/csaf/white/2026/ids-2026-0001.html | [email protected] | AdvisoryBundleRemedyVendor |
| https://www.innomic.com/.well-known/csaf/white/2026/ids-2026-0001.json | [email protected] | AdvisoryBundleRemedyVendor |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-306 | Missing Authentication for Critical Function | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| IDS Innomic VibroLine VLE1 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine VLE2 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine VLE4 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine VLE6 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine VLE8 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine VLX1 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine VLX2 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine VLX4 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine VLX6 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine VLX8 HD 5.0 | All versions |
CPE
Remediation
| |
| IDS Innomic VibroLine 5.0 Firmware | >= 2.1.1340, <= 2.1.1387 (semver) |
CPE
Remediation
| |
| IDS Innomic VibroLine Configurator 5.0 | >= 5.0.2416, <= 5.0.2486 (semver) |
CPE
Remediation
| |
Change History
3 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Jun 17, 2026 | CVE Modified | CISA-ADP |
| Feb 2, 2026 | New CVE Received | [email protected] |
Volerion