CVE-2022-25753 Details
Description
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf | CVE | MitigationPatchVendor Advisory |
| https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf | [email protected] | MitigationPatchVendor Advisory |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-787 | Out-of-bounds Write | [email protected] |
| CWE-121 | Stack-based Buffer Overflow | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| siemens scalance x302-7eec firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x302-7eec | All versions |
CPE
Remediation
| |
| siemens scalance x304-2fe firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x304-2fe | All versions |
CPE
Remediation
| |
| siemens scalance x306-1ldfe firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x306-1ldfe | All versions |
CPE
Remediation
| |
| siemens scalance x307-2eec firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x307-2eec | All versions |
CPE
Remediation
| |
| siemens scalance x307-3 firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x307-3 | All versions |
CPE
Remediation
| |
| siemens scalance x307-3ld firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x307-3ld | All versions |
CPE
Remediation
| |
| siemens scalance x308-2 firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x308-2 | All versions |
CPE
Remediation
| |
| siemens scalance x308-2ld firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x308-2ld | All versions |
CPE
Remediation
| |
| siemens scalance x308-2lh firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x308-2lh | All versions |
CPE
Remediation
| |
| siemens scalance x308-2lh+ firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x308-2lh+ | All versions |
CPE
Remediation
| |
| siemens scalance x308-2m firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x308-2m | All versions |
CPE
Remediation
| |
| siemens scalance x308-2m poe firmware | All versions |
CPE
Remediation
| |
| siemens scalance x308-2m poe | All versions |
CPE
Remediation
| |
| siemens scalance x308-2m ts firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x308-2m ts | All versions |
CPE
Remediation
| |
| siemens scalance x310 firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x310 | All versions |
CPE
Remediation
| |
| siemens scalance x310fe firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x310fe | All versions |
CPE
Remediation
| |
| siemens scalance x320-1fe firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x320-1fe | All versions |
CPE
Remediation
| |
| siemens scalance x320-1-2ldfe firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x320-1-2ldfe | All versions |
CPE
Remediation
| |
| siemens scalance x408-2 firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance x408-2 | All versions |
CPE
Remediation
| |
| siemens scalance xr324-4m eec firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance xr324-4m eec | All versions |
CPE
Remediation
| |
| siemens scalance xr324-4m poe firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance xr324-4m poe | All versions |
CPE
Remediation
| |
| siemens scalance xr324-4m poe ts firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance xr324-4m poe ts | All versions |
CPE
Remediation
| |
| siemens scalance xr324-12m firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance xr324-12m | All versions |
CPE
Remediation
| |
| siemens scalance xr324-12m ts firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens scalance xr324-12m ts | All versions |
CPE
Remediation
| |
| siemens siplus net scalance x308-2 firmware | < 4.1.4 |
CPE
Remediation
| |
| siemens siplus net scalance x308-2 | All versions |
CPE
Remediation
| |
Change History
4 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Apr 19, 2022 | Initial Analysis | [email protected] |