Not a U.S. government website. NDD is an independent vulnerability database by Volerion and is not affiliated with or endorsed by NIST or NVD.
CVE-2021-40142 Details
Description
In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf | CVE | PatchThird Party Advisory |
| https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf | CVE | PatchVendor Advisory |
| https://opcfoundation.org/security-bulletins/ | CVE | Vendor Advisory |
| https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf | [email protected] | PatchThird Party Advisory |
| https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf | [email protected] | PatchVendor Advisory |
| https://opcfoundation.org/security-bulletins/ | [email protected] | Vendor Advisory |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-119 | Improper Restriction of Operations within the Bounds of a Memory Buffer | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| opcfoundation local discover server | < 1.04.402.463 |
CPE
Remediation
| |
| siemens simatic process historian opc ua server firmware | < 2022 2022 - |
CPE
Remediation
| |
| siemens simatic process historian opc ua server | All versions |
CPE
Remediation
| |
| siemens simatic net pc | 14 - 15 - 16 - 17 - |
CPE
Remediation
| |
| siemens simatic wincc | All versions |
CPE
Remediation
| |
| siemens simatic wincc runtime | All versions |
CPE
Remediation
| |
| siemens simatic wincc unified scada runtime | All versions |
CPE
Remediation
| |
| siemens telecontrol server basic | 3.0 |
CPE
Remediation
| |
Change History
6 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Sep 3, 2022 | Modified Analysis | [email protected] |
| May 10, 2022 | CVE Modified | [email protected] |