CVE-2021-32983 Details
Description
A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter keyword before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-238-03 | CVE | Third Party AdvisoryUS Government Resource |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-238-03 | [email protected] | Third Party AdvisoryUS Government Resource |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-89 | Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| deltaww diaenergie | <= 1.7.5 |
CPE
Remediation
| |
Change History
5 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Sep 7, 2021 | Reanalysis | [email protected] |
| Sep 3, 2021 | Initial Analysis | [email protected] |