CVE-2021-31401 Details
Description
An issue was discovered in tcp_rcv() in nptcp.c in HCC embedded InterNiche 4.0.1. The TCP header processing code doesn't sanitize the value of the IP total length field (header length + data length). With a crafted IP packet, an integer overflow occurs whenever the value of the IP data length is calculated by subtracting the length of the header from the total length of the IP packet.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf | CVE | MitigationThird Party Advisory |
| https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/ | CVE | MitigationThird Party Advisory |
| https://www.kb.cert.org/vuls/id/608209 | CVE | Third Party AdvisoryUS Government Resource |
| https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf | [email protected] | MitigationThird Party Advisory |
| https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/ | [email protected] | MitigationThird Party Advisory |
| https://www.kb.cert.org/vuls/id/608209 | [email protected] | Third Party AdvisoryUS Government Resource |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-20 | Improper Input Validation | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| hcc-embedded nichestack | < 4.3 |
CPE
Remediation
| |
| siemens sentron 3wl com35 firmware | < 1.2.0 |
CPE
Remediation
| |
| siemens sentron 3wl com35 | All versions |
CPE
Remediation
| |
| siemens sentron 3wa com190 firmware | < 2.0.0 |
CPE
Remediation
| |
| siemens sentron 3wa com190 | All versions |
CPE
Remediation
| |
Change History
4 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Aug 26, 2021 | Initial Analysis | [email protected] |