CVE-2020-6962 Details
Description
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://www.us-cert.gov/ics/advisories/icsma-20-023-01 | CVE | Third Party AdvisoryUS Government Resource |
| https://www.us-cert.gov/ics/advisories/icsma-20-023-01 | [email protected] | Third Party AdvisoryUS Government Resource |
| https://www3.gehealthcare.com/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf | [email protected] | Product |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-20 | Improper Input Validation | [email protected] |
| CWE-20 | Improper Input Validation | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| gehealthcare apexpro telemetry server firmware | <= 4.2 4.3 |
CPE
Remediation
| |
| gehealthcare apexpro telemetry server | All versions |
CPE
Remediation
| |
| gehealthcare carescape b450 monitor firmware | 2.0 |
CPE
Remediation
| |
| gehealthcare carescape b450 monitor | All versions |
CPE
Remediation
| |
| gehealthcare carescape b650 monitor firmware | 1.0 2.0 |
CPE
Remediation
| |
| gehealthcare carescape b650 monitor | All versions |
CPE
Remediation
| |
| gehealthcare carescape b850 monitor firmware | 1.0 2.0 |
CPE
Remediation
| |
| gehealthcare carescape b850 monitor | All versions |
CPE
Remediation
| |
| gehealthcare carescape central station mai700 firmware | 1.0 2.0 |
CPE
Remediation
| |
| gehealthcare carescape central station mai700 | All versions |
CPE
Remediation
| |
| gehealthcare carescape central station mas700 firmware | 1.0 2.0 |
CPE
Remediation
| |
| gehealthcare carescape central station mas700 | All versions |
CPE
Remediation
| |
| gehealthcare clinical information center mp100d firmware | 4.0 5.0 |
CPE
Remediation
| |
| gehealthcare clinical information center mp100d | All versions |
CPE
Remediation
| |
| gehealthcare clinical information center mp100r firmware | 4.0 5.0 |
CPE
Remediation
| |
| gehealthcare clinical information center mp100r | All versions |
CPE
Remediation
| |
| gehealthcare carescape telemetry server mp100r firmware | <= 4.2 4.3 |
CPE
Remediation
| |
| gehealthcare carescape telemetry server mp100r | All versions |
CPE
Remediation
| |
Change History
5 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Mar 17, 2020 | Reanalysis | [email protected] |
| Feb 3, 2020 | Initial Analysis | [email protected] |