An issue was discovered in HCC Nichestack 3.0. The code that generates Initial Sequence Numbers (ISNs) for TCP connections derives the ISN from an insufficiently random source. As a result, an attacker may be able to determine the ISN of current and future TCP connections and either hijack existing ones or spoof future ones. (Proper ISN generation should aim to follow at least the specifications outlined in RFC 6528.)
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf | CVE | MitigationThird Party Advisory |
| https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/ | CVE | MitigationThird Party Advisory |
| https://www.hcc-embedded.com | CVE | Product |
| https://www.kb.cert.org/vuls/id/608209 | CVE | Third Party AdvisoryUS Government Resource |
| https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf | [email protected] | MitigationThird Party Advisory |
| https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/ | [email protected] | MitigationThird Party Advisory |
| https://www.hcc-embedded.com | [email protected] | Product |
| https://www.kb.cert.org/vuls/id/608209 | [email protected] | Third Party AdvisoryUS Government Resource |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-330 | Use of Insufficiently Random Values | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| hcc-embedded nichestack | 3.0 |
CPE
Remediation
| |
| siemens sentron 3wa com190 firmware | < 2.0.0 |
CPE
Remediation
| |
| siemens sentron 3wa com190 | All versions |
CPE
Remediation
| |
| siemens sentron 3wl com35 firmware | < 1.2.0 |
CPE
Remediation
| |
| siemens sentron 3wl com35 | All versions |
CPE
Remediation
| |
Change History
5 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Aug 26, 2021 | Reanalysis | [email protected] |
| Aug 26, 2021 | Initial Analysis | [email protected] |