CVE-2020-24685 Details
Description
An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service (DoS) vulnerability. Vulnerability allows attacker to stop the PLC. After stopping (ERR LED flashing red), physical access to the PLC is required in order to restart the application. This issue affects: ABB AC500 V2 products with onboard Ethernet version 2.8.4 and prior versions.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://search.abb.com/library/Download.aspx?DocumentID=3ADR010667&LanguageCode=en&DocumentPartId=&Action=Launch | CVE | PatchVendor Advisory |
| https://search.abb.com/library/Download.aspx?DocumentID=3ADR010667&LanguageCode=en&DocumentPartId=&Action=Launch | [email protected] | PatchVendor Advisory |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-770 | Allocation of Resources Without Limits or Throttling | [email protected] |
| CWE-789 | Memory Allocation with Excessive Size Value | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| abb ac500 cpu firmware | < 2.8.5 |
CPE
Remediation
| |
| abb pm573-eth | 2.0 |
CPE
Remediation
| |
| abb pm583-eth | 2.0 |
CPE
Remediation
| |
Change History
4 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Feb 16, 2021 | Initial Analysis | [email protected] |