CVE-2020-10265 Details
Description
Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-306 | Missing Authentication for Critical Function | [email protected] |
| CWE-306 | Missing Authentication for Critical Function | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| universal-robots ur software | >= 3.0.14989, <= 3.3.3.292 >= 1.4 >= 5.0 |
CPE
Remediation
| |
| universal-robots ur10 | All versions |
CPE
Remediation
| |
| universal-robots ur3 | All versions |
CPE
Remediation
| |
| universal-robots ur5 | All versions |
CPE
Remediation
| |
| universal-robots ur10e | All versions |
CPE
Remediation
| |
| universal-robots ur3e | All versions |
CPE
Remediation
| |
| universal-robots ur5e | All versions |
CPE
Remediation
| |
Change History
5 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Apr 12, 2022 | Vendor Comment | [email protected] |
| Apr 6, 2020 | Initial Analysis | [email protected] |