CVE-2019-6540 Details
Description
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01 | CVE | Third Party AdvisoryUS Government Resource |
| http://www.securityfocus.com/bid/107544 | CVE | Broken Link |
| https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01 | [email protected] | Third Party AdvisoryUS Government Resource |
| http://www.securityfocus.com/bid/107544 | [email protected] | Broken Link |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-319 | Cleartext Transmission of Sensitive Information | [email protected] |
| CWE-319 | Cleartext Transmission of Sensitive Information | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| medtronic mycarelink monitor 24950 firmware | All versions |
CPE
Remediation
| |
| medtronic mycarelink monitor 24950 | All versions |
CPE
Remediation
| |
| medtronic mycarelink monitor 24952 firmware | All versions |
CPE
Remediation
| |
| medtronic mycarelink monitor 24952 | All versions |
CPE
Remediation
| |
| medtronic carelink monitor 2490c firmware | All versions |
CPE
Remediation
| |
| medtronic carelink monitor 2490c | All versions |
CPE
Remediation
| |
| medtronic carelink 2090 firmware | All versions |
CPE
Remediation
| |
| medtronic carelink 2090 | All versions |
CPE
Remediation
| |
| medtronic amplia crt-d firmware | All versions |
CPE
Remediation
| |
| medtronic amplia crt-d | All versions |
CPE
Remediation
| |
| medtronic claria crt-d firmware | All versions |
CPE
Remediation
| |
| medtronic claria crt-d | All versions |
CPE
Remediation
| |
| medtronic compia crt-d firmware | All versions |
CPE
Remediation
| |
| medtronic compia crt-d | All versions |
CPE
Remediation
| |
| medtronic concerto crt-d firmware | All versions |
CPE
Remediation
| |
| medtronic concerto crt-d | All versions |
CPE
Remediation
| |
| medtronic concerto ii crt-d firmware | All versions |
CPE
Remediation
| |
| medtronic concerto ii crt-d | All versions |
CPE
Remediation
| |
| medtronic consulta crt-d firmware | All versions |
CPE
Remediation
| |
| medtronic consulta crt-d | All versions |
CPE
Remediation
| |
| medtronic evera icd firmware | All versions |
CPE
Remediation
| |
| medtronic evera icd | All versions |
CPE
Remediation
| |
| medtronic maximo ii crt-d firmware | All versions |
CPE
Remediation
| |
| medtronic maximo ii crt-d | All versions |
CPE
Remediation
| |
| medtronic maximo ii icd firmware | All versions |
CPE
Remediation
| |
| medtronic maximo ii icd | All versions |
CPE
Remediation
| |
| medtronic mirro icd firmware | All versions |
CPE
Remediation
| |
| medtronic mirro icd | All versions |
CPE
Remediation
| |
| medtronic nayamed nd icd firmware | All versions |
CPE
Remediation
| |
| medtronic nayamed nd icd | All versions |
CPE
Remediation
| |
| medtronic primo icd firmware | All versions |
CPE
Remediation
| |
| medtronic primo icd | All versions |
CPE
Remediation
| |
| medtronic protecta icd firmware | All versions |
CPE
Remediation
| |
| medtronic protecta icd | All versions |
CPE
Remediation
| |
| medtronic protecta crt-d firmware | All versions |
CPE
Remediation
| |
| medtronic protecta crt-d | All versions |
CPE
Remediation
| |
| medtronic secura icd firmware | All versions |
CPE
Remediation
| |
| medtronic secura icd | All versions |
CPE
Remediation
| |
| medtronic virtuoso icd firmware | All versions |
CPE
Remediation
| |
| medtronic virtuoso icd | All versions |
CPE
Remediation
| |
| medtronic virtuoso ii icd firmware | All versions |
CPE
Remediation
| |
| medtronic virtuoso ii icd | All versions |
CPE
Remediation
| |
| medtronic visia af icd firmware | All versions |
CPE
Remediation
| |
| medtronic visia af icd | All versions |
CPE
Remediation
| |
| medtronic viva crt-d firmware | All versions |
CPE
Remediation
| |
| medtronic viva crt-d | All versions |
CPE
Remediation
| |
Change History
8 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| May 22, 2025 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Nov 3, 2021 | Modified Analysis | [email protected] |
| Oct 9, 2019 | CVE Modified | [email protected] |
| Apr 8, 2019 | Initial Analysis | [email protected] |
| Mar 27, 2019 | CVE Modified | [email protected] |