A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.

Metrics

CVSS 3.x Severity and Vector Strings:

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.

URLSource(s)Tag(s)
https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02 CVEThird Party AdvisoryUS Government Resource
https://www.exploit-db.com/exploits/45918/ CVEExploitThird Party AdvisoryVDB Entry
http://www.securityfocus.com/bid/97254 CVEThird Party AdvisoryVDB Entry
https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02 [email protected]Third Party AdvisoryUS Government Resource
https://www.exploit-db.com/exploits/45918/ [email protected]ExploitThird Party AdvisoryVDB Entry

see all 6 references

Weakness Enumeration

CWE-IDCWE NameSource
CWE-330Use of Insufficiently Random Values[email protected]
CWE-330Use of Insufficiently Random Values[email protected]

Affected Products

ProductVersions
schneider-electric modicon m251 firmware
<= 4.0.3.20

CPE

  • cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*

Remediation

  • No remediation found in references.
schneider-electric modicon m251
All versions

CPE

  • cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*

Remediation

  • No remediation found in references.
schneider-electric modicon m241 firmware
<= 4.0.3.20

CPE

  • cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*

Remediation

  • No remediation found in references.
schneider-electric modicon m241
All versions

CPE

  • cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*

Remediation

  • No remediation found in references.

Change History

19 change records found show changes


QUICK INFO

CVE Dictionary Entry:
CVE-2017-6026
NVD Published Date:
Jun 30, 2017
NVD Last Modified:
Jun 17, 2026
Source:
[email protected]
CVE-2017-6026 Details - Not Deferred