Not a U.S. government website. NDD is an independent vulnerability database by Volerion and is not affiliated with or endorsed by NIST or NVD.
CVE-2017-18922 Details
Description
It was discovered that websockets.c in LibVNCServer prior to 0.9.12 did not properly decode certain WebSocket frames. A malicious attacker could exploit this by sending specially crafted WebSocket frames to a server, causing a heap-based buffer overflow.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-787 | Out-of-bounds Write | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| libvncserver project libvncserver | < 0.9.12 |
CPE
Remediation
| |
| canonical ubuntu linux | 16.04 18.04 19.10 20.04 |
CPE
Remediation
| |
| opensuse leap | 15.1 15.2 |
CPE
Remediation
| |
| fedoraproject fedora | 31 32 |
CPE
Remediation
| |
| siemens simatic itc1500 firmware | >= 3.0.0.0, < 3.2.1.0 |
CPE
Remediation
| |
| siemens simatic itc1500 | All versions |
CPE
Remediation
| |
| siemens simatic itc1500 pro firmware | >= 3.0.0.0, < 3.2.1.0 |
CPE
Remediation
| |
| siemens simatic itc1500 pro | All versions |
CPE
Remediation
| |
| siemens simatic itc1900 firmware | >= 3.0.0.0, < 3.2.1.0 |
CPE
Remediation
| |
| siemens simatic itc1900 | All versions |
CPE
Remediation
| |
| siemens simatic itc1900 pro firmware | >= 3.0.0.0, < 3.2.1.0 |
CPE
Remediation
| |
| siemens simatic itc1900 pro | All versions |
CPE
Remediation
| |
| siemens simatic itc2200 firmware | >= 3.0.0.0, < 3.2.1.0 |
CPE
Remediation
| |
| siemens simatic itc2200 | All versions |
CPE
Remediation
| |
| siemens simatic itc2200 pro firmware | >= 3.0.0.0, < 3.2.1.0 |
CPE
Remediation
| |
| siemens simatic itc2200 pro | All versions |
CPE
Remediation
| |
Change History
17 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Nov 7, 2023 | CVE Modified | [email protected] |
| Apr 1, 2022 | Modified Analysis | [email protected] |
| Dec 14, 2021 | CVE Modified | [email protected] |
| Jul 24, 2020 | CVE Modified | [email protected] |
| Jul 23, 2020 | Modified Analysis | [email protected] |
| Jul 21, 2020 | CVE Modified | [email protected] |
| Jul 18, 2020 | CVE Modified | [email protected] |
| Jul 18, 2020 | CVE Modified | [email protected] |
| Jul 16, 2020 | CVE Modified | [email protected] |
| Jul 15, 2020 | CVE Modified | [email protected] |
| Jul 15, 2020 | CVE Modified | [email protected] |
| Jul 14, 2020 | CVE Modified | [email protected] |
| Jul 6, 2020 | Initial Analysis | [email protected] |
| Jun 30, 2020 | CVE Modified | [email protected] |