CVE-2017-11578 Details
Description
It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack.
Metrics
CVSS 4.0 Severity and Vector Strings:
No CVSS 4.0 data is available for this CVE.
CVSS 3.x Severity and Vector Strings:
No data available for CVSS Version 2.0 on this CVE.
No SSVC data is available for this CVE.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving this site. These are references gathered from the official CVE record and are not endorsed by Volerion.
| URL | Source(s) | Tag(s) |
|---|---|---|
| http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html | CVE | Third Party AdvisoryVDB Entry |
| https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf | CVE | ExploitThird Party Advisory |
| https://seclists.org/bugtraq/2019/Jun/8 | CVE | Mailing ListThird Party Advisory |
| http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html | [email protected] | Third Party AdvisoryVDB Entry |
| https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf | [email protected] | ExploitThird Party Advisory |
| https://seclists.org/bugtraq/2019/Jun/8 | [email protected] | Mailing ListThird Party Advisory |
Weakness Enumeration
| CWE-ID | CWE Name | Source |
|---|---|---|
| CWE-200 | Exposure of Sensitive Information to an Unauthorized Actor | [email protected] |
Affected Products
| Product | Versions |
|---|---|
| blipcare wi-fi blood pressure monitor firmware | <= bp700_10.1 |
CPE
Remediation
| |
| blipcare wi-fi blood pressure monitor | All versions |
CPE
Remediation
| |
Change History
4 change records found show changes
| Date | Action | Recorded By |
|---|---|---|
| Jun 17, 2026 | CVE Modified | [email protected] |
| Nov 21, 2024 | CVE Modified | CVE |
| May 14, 2024 | CVE Modified | [email protected] |
| Jul 15, 2019 | Initial Analysis | [email protected] |